50w 12v 4.2a 220vac to 12vdc converter power supply S-50-12

Input current:2A/115VAC          1A/230VAC

Output current range:0-10A

DC output power:50W

Overall dimension:159*97*38mm (L*W*H)

  • Description
  • PDF Datasheet
ModelS-50-5S-50-12S-50-15S-50-24
OutputDC Voltage5V12V15V24V
Rated Current10A4.2A3.3A2A
Current Range0~10A0~4.2A0~4.3A0~2A
Rated Power50W50W49.5W48W
Ripple & Noise (max.) Note.2120mVp-p120mVp-p150mVp-p150mVp-p
Voltage Adj. Range4.75~5.5V10.8~13.2V13.5~16.5V21.6~26.4V
Voltage Tolerance Note.3±2.0%±1.0%±1.0%±1.0%
Line Regulation±0.5%±0.5%±0.5%±0.5%
Load Regulation±1.0%±0.5%±0.5%±0.5%
Setup,Rise time300ms, 50ms/230VAC 800ms, 50ms/115VAC at full load
Hold time80ms/230VAC 12ms/115VAC at full load
InputVoltage Range85 ~ 264VAC         120 ~ 370VDC
Frequency Range47~63HZ
Efficiency(Typ.)73%76%77%79%
AC Current(Typ.)2A/115VAC          1A/230VAC
Inrush Current (Typ.)COLD START 20A/115VAC          40A/230VAC
Leakage Current<3.5mA / 240VAC
ProtectionOver Load105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Over Voltage5.75 ~ 6.75V13.8 ~ 16.2V17.25 ~ 20.25V27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
EnvironmentWorking Temperature-10 ~ +60°c (Refer to “Derating Curve” )
Working Humidity20~90% RH  Non-condensing
Storage temp.& humidity-20~+85°C, 10~95%RH
Temp. coefficient±0.03%/°C (0~50°C)
Vibration10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety & EMC

(Note 4.)

Safety StandardsUL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved
Withstand VoltageI/P-O/P:1.5KVAC     I/P-FG:1.5KVAC     O/P-FG:0.5KVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/ 25°c / 70% RH
EMC EmissionCompliance to  EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC ImmunityCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,  criteria A
OthersMTBF316.2K hrs min.      MIL-HDBK-217F (25°c )
Dimension159*97*38mm (L*W*H)
Packing0.51Kg; 30pcs/19Kg/0.7CUFT
Note1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.