S-120-12 Switching Power Supply 120w 12v 10a

Input current:3.15A/115VAC          1.5A/230VAC

Output current range:0~24A

DC output power:120W

Overall dimension:199*98*38mm (L*W*H)

  • Description
  • PDF Datasheet
ModelS-120-5S-120-7.5S-120-12S-120-15S-120-24S-120-48
OutputDC Voltage5V7.5V12V15V24V48V
Rated Current24A16A10A8A5A2.5A
Current Range0~24A0~160~10A0~8A0~5A0~2.5A
Rated Power120W120W120W120W120W120W
Ripple & Noise (max.) Note.2100mVp-p125mVp-p125mVp-p125mVp-p150mVp-p150mVp-p
Voltage Adj. Range4.5~5.5V6.75~8.25V10.8~13.2V13.5~16.5V21.6~26.4V43.2~52.8V
Voltage Tolerance Note.3±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%
Line Regulation±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%
Load Regulation±1.0%±0.5%±0.5%±0.5%±0.5%±0.5%
Setup,Rise time1000ms, 30ms at full load
Hold time (Typ.)20ms at full load
InputVoltage Range88 ~ 132VAC/176 ~ 264VAC selected by jumper or switch          248 ~ 370VDC
Frequency Range47~63HZ
Efficiency(Typ.)76%78%80%81%83%84%
AC Current(Typ.)3.15A/115VAC          1.5A/230VAC
Inrush Current (Typ.)COLD START 20A/115VAC          40A/230VAC
Leakage Current
ProtectionOver Load105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Over Voltage5.75 ~ 6.75V8.63~10.13V13.8 ~ 16.2V17.25 ~ 20.25V27.6 ~ 32.4V55.2~64.8
Protection type : Hiccup mode, recovers automatically after fault condition is removed
EnvironmentWorking Temperature-10 ~ +60°c (Refer to “Derating Curve” )
Working Humidity20~90% RH  Non-condensing
Storage temp.& humidity-20~+85°C, 10~95%RH
Temp. coefficient±0.03%/°C (0~50°C)
Vibration10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety & EMC

(Note 4.)

Safety StandardsUL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved
Withstand VoltageI/P-O/P:1.5KVAC     I/P-FG:1.5KVAC     O/P-FG:0.5KVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/ 25°c / 70% RH
EMC EmissionCompliance to  EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC ImmunityCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,  criteria A
OthersMTBF314.9K hrs min.      MIL-HDBK-217F (25 °c)
Dimension199*98*38mm (L*W*H)
Packing0.65Kg; 20pcs/14.2Kg/0.8CUFT
Note1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

Online Service