single output S-25 25w smps 24v switch mode power supply led transformer

Input current:0.6A/115VAC         0.35A/230VAC

Output current range:0~5A

DC output power:25W

Overall dimension:99*97*36mm (L*W*H)

  • Description
  • PDF Datasheet
ModelS-25-5S-25-12S-25-15S-25-24
OutputDC Voltage5V12V15V24V
Rated Current5A2.1A1.7A1.1A
Current Range0~5A0~2.1A0~1.7A0~1.1A
Rated Power25W25.2W25.5W26.4W
Ripple & Noise (max.) Note.250mVp-p100mVp-p100mVp-p100mVp-p
Voltage Range4.75~5.5V10.8~13.2V13.5~16.5V21.6~26.4V
Voltage Tolerance Note.3±2.0%±1.0%±1.0%±1.0%
Line Regulation±0.5%±0.5%±0.5%±0.5%
Load Regulation±1.0%±0.5%±0.5%±0.5%
Setup,Rise, Hold time300ms, 50ms, 80ms/230VAC       800ms, 50ms, 10ms/115VAC at full load
InputVoltage Range85 ~ 132VAC / 170 ~ 264VAC selected by switch         240 ~ 370VDC
Frequency Range47~63HZ
Efficiency(Typ.)72%/115VAC76%/115VAC77%/115VAC80%/115VAC
AC Current0.6A/115VAC         0.35A/230VAC
Inrush Current (max.)COLD START 15A/115VAC         30A/230VAC
Leakage Current
ProtectionOver Load110~115% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
Over Voltage5.75V~6.75V13.8V~16.2V17.25V~20.25V27.6V~32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
EnvironmentWorking Temperature-10 ~ +60°c (Refer to output load derating curve)
Working Humidity20~90% RH Non-condensing
Storage temp.& humidity-20~+85°C, 10~95%RH
Temp. coefficient±0.03%/°C (0~50°C)
Vibration10 ~ 500Hz, 2G 10min./1 cycle,60min.each along X,Y,Z axes
Safety & EMC (Note 4.)Safety StandardsUL1012, TUV EN60950-1 Approved
Withstand VoltageI/P-O/P:3KVAC     I/P-FG:1.5KVAC     O/P-FG:0.5KVAC
Isolation ResistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI Conduction & RadiationCompliance to EN55022 (CISPR22) Class B
Harmonic CurrentCompliance to EN61000-3-2,-3
EMS ImmunityCompliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A
OthersMTBF330.8K hrs min.     MIL-HDBK-217F (25°c )
Dimension99*97*36mm (L*W*H)
Packing0.39Kg; 45pcs/18Kg/0.9CUFT
Note1. All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 10uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.